In electrical engineering, a protective relay is an electromechanical apparatus, often with more than one coil, designed to calculate operating conditions on an electrical circuit and trip circuit breakers when a fault is detected. Unlike switching type relays with fixed and usually ill-defined operating voltage thresholds and operating times, protective relays have well-established, selectable, time/current (or other operating parameter) operating characteristics. Protection relays may use arrays of induction disks, shaded-pole magnets, operating and restraint coils, solenoid-type operators, telephone-relay contacts, and phase-shifting networks. Protection relays respond to such conditions as over-current, over-voltage, reverse power flow, over- and under- frequency. Distance relays trip for faults up to a certain distance away from a substation but not beyond that point. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices. The various protective functions available on a given relay are denoted by standard ANSI Device Numbers. For example, a relay including function 51 would be a timed overcurrent protective relay.


  1. Introduction to Power Systems Relaying
    •    System Planning
    •    Power System Studies
    •    Phasor Fundamentals
    •    Relaying Principles
    •    Review of Short Circuit Calculations
    •    Fundamentals of Coordination
  2. Power Systems Grounding
    •    Symmetrical Components
    •    Ungrounded Systems
    •    Solidly-Grounded Systems
    •    Resistance-Grounded Systems
    •    Ground Fault Detection Methods
  3. Current Transformers
    •    Types, CT Ratios, Polarity
    •    Burden, Accuracy Classes, Saturation Calculations
  4. Protection Fundamentals
    •    Line, Cables, Feeders
    •    Medium Voltage Motors
    •    Power Transformers
  5. Protective Relay Schemes
    •    Directional Relays
    •    Differential Relays
    •    Ground Relays



Application engineers, design engineers and electrical engineers from industrial or municipal distribution systems with complex protective relay


Miftahul Huda, ST., MEng






  • Hotel Merapi Merbabu  Yogyakarta
  • 13-15 Juli, 18-120 Agustus, 15-17 September, 26-28 Oktober, 17-19 November, 21-23 Desember
  • 08.00  – 16.00 WIB



  • Biaya Rp. 8.500.000 per peserta (Non Residential).
  • Pembayaran dapat dilakukan pada saat pelatihan


Training Modules, Training Kit, Certificate, Exclusive Souvenir, Dinner & City Tour, Coffee Break & Lunch

Share and Enjoy: These icons link to social bookmarking sites where readers can share and discover new web pages.
  • MisterWong
  • Y!GG
  • Webnews
  • Digg
  • StumbleUpon
  • Reddit
Posted in: Electrical, Yogyakarta

About the Author:

Post a Comment